Skip to content
Used, reconditioned and new IBC totes275 and 330 gallon sizesSell or recycle your emptiesPickup and delivery through partner suppliersFree, no-obligation quote requestsRequests from across the USUsed, reconditioned and new IBC totes275 and 330 gallon sizesSell or recycle your emptiesPickup and delivery through partner suppliersFree, no-obligation quote requestsRequests from across the US
Menu
IBC TotesTote quote requests
Industries · IN-03

Chemical & Industrial

A washed Grade A container with a known prior-contents history and the right valve seat is a better choice than a cosmetically perfect one with an unknown past. Include the SDS with your request.

  • Send the SDS so prior contents and seat can be matched
  • Viton for hydrocarbons and oxidisers, EPDM for caustics and dilute acids
  • Vented caps for products that give off gas
  • Steel bases for dense products
UN 31HA1/YLot IN-03Grade A
Compatibility first, cosmetics second

Start a request

Quote requestFree · no obligation

A working email address

US or Canadian phone number, 10 digits

US ZIP or Canadian postal code

A partner supplier in our network follows up. Fields marked * are required.
What to check · IN-03
QuestionThis sector
Prior contents that usually suitCaustics, dilute acids, glycols, surfactants, coolants, water treatment chemistry
ConditionalHypochlorite — vented cap needed; oils — caustic wash and odour check
Prior contents to avoidAromatic solvents and fuels in any container meant for refill
Cleaning usually neededCaustic wash
Valve seatMatched from SDS — EPDM, Viton or PTFE-lined
Pallet baseSteel for dense products and acids
What to ask for
  • Reconditioned Grade A
    General industrial refill with a matched seat
  • Grade A with a current UN test
    Regulated hazardous materials on public roads
  • Stainless steel
    Chlorides, aggressive acids and closed-loop use
Answer first

For industrial chemistry, reconditioned Grade A with a valve seat matched to your product is the usual request. If the filled container moves on a public road as a regulated hazardous material, you also need a container with a valid UN marking and a current periodic test; check current regulations. Pricing is by quote.

Compatibility is a two-sided question

Most buyers check whether their product is compatible with HDPE and stop there. The second question matters as much: is your product compatible with whatever the container held before it?

A tote that held a strong oxidiser and still carries trace residue is a poor home for an organic concentrate. One that held an acid is a poor home for hypochlorite. That is why the prior-contents record matters.

The valve seat matters more than the grade

EPDM handles water, caustics, dilute acids and much industrial chemistry. Viton is generally used for hydrocarbons, aromatic solvents and strong oxidisers. PTFE-lined seats cover the aggressive end.

An EPDM seat in a hydrocarbon swells, loses its seal and leaks. Check the seat against a compatibility chart and your SDS, and ask for the right one in your request.

Regulated transport changes the requirement

If the filled container travels on a public road as a regulated hazardous material, it needs a valid UN design type marking and a current periodic test. Check current regulations for the retest intervals that apply.

An old UN plate is not a current test. Read the test date on the marking before relying on it.

Why mismatched pairings should be turned down

A container whose prior residue is incompatible with your product is the wrong container, however clean it looks. Containers with unknown hazardous, radiological or biological histories should not be reused at all.

A supplier who will sell any container for any product is not checking. Expect questions about your product, and answer them.

A single IBC toteSDS matched
A single IBC tote.
The two-sided question

Compatibility is not just your product and the plastic

Most buyers check whether their product is compatible with HDPE and stop there. The second question matters as much: is your product compatible with whatever the container held before?

A container that held a strong oxidiser is a poor home for an organic concentrate. One that held an acid is a poor home for hypochlorite. These are ordinary situations with used containers, and they are why the prior-contents record matters.

Send the safety data sheet with your request so both sides can be checked: the prior contents against your product, and the seat material against your chemistry.

Request a quote
Compatibility reference

Seat, base and cap by chemical family

A general guide to fittings by chemical family, with what goes wrong when the choice is wrong. Always check against your SDS and a compatibility chart.

Compatibility is a two-sided question. Most buyers check their product against HDPE and stop; the second question is whether their product is compatible with whatever the container held before.

Include the safety data sheet in your request so the partner supplier who quotes can check both sides.

Chemical familySeatCapBaseIf the choice is wrong
Caustic sodaEPDMVentedSteel for strong solutionsSeat hardening at high strength
Dilute mineral acidsEPDMVentedSteelSeat swelling at higher strength
Concentrated acidsPTFE-linedVentedSteel, or a different containerWeight beyond the base or forklift
Sodium hypochloriteViton or PTFE-linedVentedSteelSeat hardens and cracks; bottle balloons
Hydrogen peroxidePTFE-linedVentedSteelDecomposition and pressure build-up
Glycols and coolantsEPDMSolidCompositeRarely an issue
Diesel and light oilsVitonSolidCompositeEPDM swells and leaks
Aromatic solventsVitonVentedCompositeSeat swell plus permanent wall permeation
Surfactant concentratesEPDMSolidCompositeRarely an issue
Some chemistry belongs in stainless or a lined vessel rather than a composite IBC at any grade. Confirm with the supplier and your SDS.

What to send with a chemical request

  1. The safety data sheet, or at least the product name and concentration.
  2. Specific gravity from the SDS, which decides the pallet base.
  3. Whether the product gives off gas, which decides the cap.
  4. Whether the filled container travels on a public road as a regulated hazardous material.
  5. Which prior contents you can accept — a compatible product, or virgin only.
  6. Your fill temperature, if it is above ambient.
Cross-sector reference

How this sector compares

The same six-row table appears on every sector page, so you can see where your own requirement sits relative to the others.

SectorWhat decides itGrade usually asked forSeatBase
AgricultureResidue compatibility; herbicide carryoverGrade A / clean BEPDMSteel for dense products
Food & beverageDocumentation and prior-use historyFood-use / rebottledSiliconeSteel or plastic
Chemical & industrialSDS compatibility and marking validityReconditioned AMatched from SDSSteel for dense
Water & wastewaterOxidiser resistance and ventingReconditioned AViton / PTFESteel for coagulants
Construction & energyRough handling and UVRinsed Grade BEPDMGalvanised steel
Breweries & distilleriesSeparating three populationsMixed by dutySilicone / EPDMPlastic or steel
More per sector on the industries hub.
FAQ

Chemical & Industrial questions

Can I store sulphuric acid in an IBC tote?

Dilute acid, often yes, with the right seat and a steel base. Concentrated acid is very dense, can exceed base and forklift ratings, and needs careful venting. Send the concentration with your request and confirm whether an IBC is the right container at all.

Will a used tote hold caustic soda?

HDPE generally handles sodium hydroxide well at ambient temperature, and EPDM seats suit it. Strong caustic solutions are dense, so specify a galvanised steel base.

Do I need a UN marked tote?

Only if the filled container moves on a public road as a regulated hazardous material. Much industrial chemistry is not regulated in transport. Check current regulations for your product.

What if my product gives off gas?

Specify a vented cap. Hypochlorite, some peroxides and anything that reacts or heats up can pressurise a sealed bottle.

Requesting totes for chemical & industrial?

Send the product, the volume and your location. We pass your request to partner suppliers in our network, and a partner supplier follows up with a quote.

Get a quoteOpens the request desk
Quote request · ibctotes.org

Tell us what you need.

One form. We pass your request to a partner supplier in our network, who follows up with a quote for the grade, fittings and delivery you need.

Quote requestFree · no obligation

A working email address

US or Canadian phone number, 10 digits

US ZIP or Canadian postal code

A partner supplier in our network follows up. Fields marked * are required.